ETJ Series – Alkaline (ALK) Electrolyzer System
The ETJ series ALK water electrolysis hydrogen production system has a maximum hydrogen output of up to 1,500 Nm³/h per unit, and includes key components such as an ALK electrolyzer, gas-liquid separation system, purification and drying system, control system, power supply system, etc. It is widely used in industrial hydrogen production, chemical feedstock supply, hydrogen refueling station integration, and other applications.
Technical Specifications
Parameter | Unit | ETJ-50 | ETJ-100 | ETJ-200 | ETJ-500 | ETJ-1000 | ETJ-1500 |
Operating Pressure | MPa | 1.6~3.2 | 1.6 | ||||
Hydrogen Output | Nm³/h | 50 | 100 | 200 | 500 | 1000 | 1500 |
Oxygen Output | Nm³/h | 25 | 50 | 100 | 250 | 500 | 750 |
Hydrogen Purity Before Purification | % | 99.8 | |||||
Oxygen Purity Before Purification | % | 98.5 | |||||
Ultrapure Water Consumption | t/h | 0.05 | 0.1 | 0.2 | 0.5 | 1 | 1.5 |
Operating Load Range | % | 30~110 | |||||
Operating Temperature | ℃ | 90±5 | |||||
Hydrogen Purity After Purification | % | 99.999 | |||||
DC Power Consumption | kW·h/Nm³ H₂ | <4.5 | |||||
KOH Electrolyte Concentration | % | 30 | |||||
System Control | / | PLC+HMI | |||||
System Safety | / | The overall system has been verified through HAZOP and LOPA analysis. | |||||
Features
Adopting advanced materials and manufacturing processes, hydrogen content in oxygen remains below 1.0% throughout 10 years of operation.
Cost advantage: Utilizes highly efficient electrodes with a non‑precious metal approach.
Flexible scalability: Cold start in 30 minutes and hot start in 5 minutes.
Green and environmentally friendly: Hydrogen is produced using only water and electricity.
Easy maintenance: Simple structure.
High compatibility: Electrolyzer operating current density ≥ 8,000 A/m²; the system supports operating load range: 30% ~ 110%.
+86-0519-88870109
+86 15906119343
welcome@eontsing.com